5.13.1 1 Specialist piped supply installations

– Piped gas supply systems of high purity (e.g. oxygen or nitrous oxide) from storage source to distribution points in medical treatment, medical research or similar establishments. – Piped distribution systems providing suction for vacuum cleaning and collection facilities. – Piped water supply systems where the water is treated to obtain a high degree of purity for special use and application. – Systems for the treatment and circulation of water for swimming pools. – Piped distribution systems providing compressed air for motive power and general purpose use. – Piped distribution systems providing compressed air of high quality (oil free) for purposes of operating pneumatic controls and other delicate instruments and equipment. – Piped distribution systems providing negative pressure at a number of points for particular user or process functions. – Other piped distributions of a specialist nature.

9 Components Element: 5.13 - Element 5.13

Components in this Sub-Element

5.13.1-1 Seq. 1

Medical and laboratory gas supply systems

Unit: nr/m2
Details to state: details of each type of system to be stated.
5.13.1-2 Seq. 2

Centralised vacuum cleaning systems

Unit: nr/m2
Details to state: details of each type of system to be stated.
5.13.1-3 Seq. 3

Treated water systems

Unit: nr/m2
Details to state: details of each type of system to be stated.
5.13.1-4 Seq. 4

Swimming pool water treatment systems

Unit: nr/m2
Details to state: details of each type of system to be stated.
5.13.1-5 Seq. 5

Compressed air systems

Unit: nr/m2
Details to state: details of each type of system to be stated.
5.13.1-6 Seq. 6

Vacuum installations

Unit: nr/m2
Details to state: details of each type of system to be stated.
5.13.1-7 Seq. 7

Other specialist piped supply systems

Unit: nr/m2
Details to state: details of each type of system to be stated.
5.13.1-8 Seq. 8

Testing of installations.

Unit: %
5.13.1-9 Seq. 9

Commissioning of installations.

Unit: %

Related Environmental Product Declarations

EPDs classified under this NRM sub-element

ec334exb

Legrand, North and Central America

ec33euja

Uponor Corporation

ec33j65z

Geberit International AG

ec342f0e

NEXANS

ec3577ub

NEXANS
AAC
Valid

ec37rk9h

NEXANS

ec387jzu

Prysmian Group Norge AS
XKDT Cu
Valid

ec38cxcj

NEXANS

ec38h3j1

Geberit International AG

ec39czpc

Groupe SM Tardif

ec39ge49

NEXANS

ec3d3cmf

NEXANS

ec3dfx5z

Brass and Fittings, S.L.

ec3ewfqk

Prysmian Group Finland Oy

ec3f7z5n

NEXANS

ec3gjgfw

NEXANS

ec3h1u7f

Global Display Solutions S.p.A.
F/UTP
Valid

ec3h8bwf

NEXANS

ec3h8jm0

NEXANS

ec3hcjxg

NEXANS

ec3hucqe

NEXANS

ec3hxc72

NEXANS

ec3k0afz

NEXANS

ec3mnwh1

NEXANS

ec3nuy8z

NEXANS

ec3p0zrq

Prysmian Group Norge AS
Sub-Element Information
Code:
5.13.1
Name:
1 Specialist piped supply installations
Element:
5.13 - Element 5.13
Group:
5 - Services
Definition:
– Piped gas supply systems of high purity (e.g. oxygen or nitrous oxide) from storage source to distribution points in medical treatment, medical research or similar establishments. – Piped distribution systems providing suction for vacuum cleaning and collection facilities. – Piped water supply systems where the water is treated to obtain a high degree of purity for special use and application. – Systems for the treatment and circulation of water for swimming pools. – Piped distribution systems providing compressed air for motive power and general purpose use. – Piped distribution systems providing compressed air of high quality (oil free) for purposes of operating pneumatic controls and other delicate instruments and equipment. – Piped distribution systems providing negative pressure at a number of points for particular user or process functions. – Other piped distributions of a specialist nature.
Classification Codes
Uniclass 2015 Codes
SS + PR Combined:
6217
SS (System/Section):
1929
PR (Product):
6576

System/Section (SS) Information
SS Code:
Ss_75_50_28_32
SS Title:
Flow sample gas detection and alarm systems
SS NBS Code:
75-65-35/120 Flow sample gas detection and alarm system;
NRM Codes Bundle:
5.13.1 Specialist piped supply installations (default);

Product (PR) Information
PR NBS Code:
90-70-95/310
PR Code Name:
Electronic sounders;
PR Title:
Electronic sounders
Product Description:
Alarm indication
Product Definition:
Products such as Electronic sounders
Statistics
9
Components
nr/m2: 7
%: 2
API Access

Access this data programmatically: