Components
53 TotalSearch & Filter Components
Active Filters:
Group: 1
Clear All
1.1.3-4 nr
Extra over lowest floor construction for forming swimming pool tanks, etc
Sub-Element:
1.1.3 - 3 Lowest floor …
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details,including the size (m), to be stated
1.1.3-5 m
Retaining walls at changes in level
Sub-Element:
1.1.3 - 3 Lowest floor …
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details, including thickness (mm),height (m) and reinforcement rate …
1.1.3-6 m
Designed joints
Sub-Element:
1.1.3 - 3 Lowest floor …
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details, including height (mm), to be stated
1.1.3-7 m
Drainage below ground
Sub-Element:
1.1.3 - 3 Lowest floor …
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details, including average depth of trench (m), type …
1.1.3-8 nr
Gullies, floor outlets, etc.
Sub-Element:
1.1.3 - 3 Lowest floor …
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details to be stated
1.1.3-9 nr
Internal manholes,catch-pits, petrol interceptors, etc.
Sub-Element:
1.1.3 - 3 Lowest floor …
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details to be stated
1.1.3-10 %
Testing of drainage installations.
Sub-Element:
1.1.3 - 3 Lowest floor …
Element:
1.1 - Element 1.1
Group:
1 - Substructure
1.1.3-11 %
Commissioning of drainage installations
Sub-Element:
1.1.3 - 3 Lowest floor …
Element:
1.1 - Element 1.1
Group:
1 - Substructure
1.1.4-1 m3
Basement excavation
Sub-Element:
1.1.4 - 4 Basement excavation
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details,including average depth of excavation, to be stated
1.1.4-2 m3
Disposal of excavated material
Sub-Element:
1.1.4 - 4 Basement excavation
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details to be stated
1.1.4-3 m3
Extra for disposal of contaminated excavated materia
Sub-Element:
1.1.4 - 4 Basement excavation
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details to be stated
1.1.4-4 m2
Earthwork support
Sub-Element:
1.1.4 - 4 Basement excavation
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details to be stated
1.1.4-5 m3
Additional excavation
Sub-Element:
1.1.4 - 4 Basement excavation
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details to be stated
1.1.5-1 m/m2
Basement retaining wall
Sub-Element:
1.1.5 - 5 Basement retaining …
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details to be stated
1.1.5-2 m2
Piling mats/platforms
Sub-Element:
1.1.5 - 5 Basement retaining …
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details,including thickness of mat/platform (mm), to be stated
1.1.5-3 item
Piling plant
Sub-Element:
1.1.5 - 5 Basement retaining …
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details to be stated
1.1.5-4 nr
Moving piling rig to pile position
Sub-Element:
1.1.5 - 5 Basement retaining …
Element:
1.1 - Element 1.1
Group:
1 - Substructure
1.1.5-5 m
Guide walls
Sub-Element:
1.1.5 - 5 Basement retaining …
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details to be stated
1.1.5-6 nr
Piles
Sub-Element:
1.1.5 - 5 Basement retaining …
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details,including type,diameter (mm), depth (m), total length (m) …
1.1.5-7 m
Contiguous bored pile walls
Sub-Element:
1.1.5 - 5 Basement retaining …
Element:
1.1 - Element 1.1
Group:
1 - Substructure
Details to state: details,including diameter (mm), depth (m), total length (m) …
53
Total Components
656
Different Units
3
Pages
API Access
Access components data programmatically:
GET /api/components/- All componentsGET /api/sub-elements/{code}/components/- Components by sub-element