5.9.1-1

Fuel storage

Unit: nr Sub-Element: 5.9.1 - 1 Fuel storage
Component Information
Code:
5.9.1-1
Sequence:
1
Unit:
nr
Sub-Element:
5.9.1 - 1 Fuel storage
Description:

Fuel storage

Details to State:

details to be stated

Component Statistics
6
Measurement Rules
8
Included Items
7
Excluded Items
Measurement Rules (6)
C1 1

Where components are to be enumerated, the number of components is to be stated.

C2 2

The area measured is the total GIFA of the building.

C3 3

Installations for residential units, hotel rooms, student accommodation units, etc. may be enumerated (nr). The type of residential unit or room, and size (by number of bedrooms) of unit, is to be stated.

C4 4

Work to existing buildings is to be described and identified separately.

C5 5

Where the contractor is only responsible for designing specific elements and/or components of the building project (i.e. not the entire building project), contractor-designed work is to be described and identified separately.

C6 6

The percentage additions for testing and commissioning are to be applied to the total cost of the items comprising the sub-element. A single combined percentage addition can be applied to cover the costs of both testing and commissioning.

Included Items (8)
1.

Gas, oil, petrol, diesel, LPG, biomass and other fuel systems.

2.

Storage tanks and vessels not supplied in connection with heat source installations.

3.

Proprietary supports forming an integral part of the storage tank/vessel unit.

4.

Off-site painting/anti-corrosion treatments.

5.

Thermal insulation.

6.

Sundry items.

7.

Testing and commissioning.

8.

Where works are to be carried out by a subcontractor, the subcontractor’s preliminaries, design fees, risk allowance, overheads and profit, with allowance for these to be made within unit rate applied to element or component.

Excluded Items (7)
1. Ref: 5.5

Storage tanks and vessels supplied as an integral part of heat source installations (included in element 5.5).

2. Ref: 8.7.7

Storage tanks and vessels external to the building (included in sub-element 8.7.7).

3. Ref: 5.14

Supports not integral to the storage tank/vessel (included in element 5.14).

4. Ref: 5.14

Fuel bunds, etc. for storage/retention tanks and vessels (included in element 5.14).

5. Ref: 5.14

On-site painting of storage tanks and vessels, supports and pipelines (included in element 5.14).

6. Ref: 5.12.3

Building management systems and other control systems (included in sub-element 5.12.3).

7. Ref: 5.14

Builder’s work in connection with services (included in element 5.14).

Export
View as JSON
API Access

Access this component data programmatically: