5.8.3-1

Lighting installation

Unit: m2 Sub-Element: 5.8.3 - 3 Lighting installations
Component Information
Code:
5.8.3-1
Sequence:
1
Unit:
m2
Sub-Element:
5.8.3 - 3 Lighting installations
Description:

Lighting installation

Details to State:

details to be stated.

Component Statistics
6
Measurement Rules
14
Included Items
5
Excluded Items
Measurement Rules (6)
C1 1

The area measured is the area serviced by the system (i.e. the area of the rooms and circulation spaces that are served by the system, which is not necessarily the total GIFA of the building). The area serviced is measured using the GIFA.

C2 2

Where more than one system is employed, the area measured for each system is the area serviced by the system.

C3 3

Installations for residential units, hotel rooms, student accommodation units, etc. may be enumerated (nr). The type of residential unit or room, and size (by number of bedrooms) of unit, is to be stated.

C4 4

Work to existing buildings is to be described and identified separately.

C5 5

Where the contractor is only responsible for designing specific elements and/or components of the building project (i.e. not the entire building project), contractor-designed work is to be described and identified separately.

C6 6

The percentage additions for testing and commissioning are to be applied to the total cost of the items comprising the sub-element. A single combined percentage addition can be applied to cover the costs of both testing and commissioning.

Included Items (14)
1.

General internal lighting, including lighting fixed to the exterior of the building (e.g. bulkhead fittings and downlights for soffits/external suspended ceilings).

2.

Emergency lighting.

3.

Lighting fixed to the exterior of the building supplied as part of the interior system.

4.

LVLV switchgear and distribution boards, where not included as part of the sub-mains distribution.

5.

Cables and wiring, including support components from sub-distribution boards to lighting points, switches, etc.

6.

Conduits and cable trunking, including all fittings and support components.

7.

Earthing and bonding.

8.

Fittings for lighting points, including roses, pendants, etc.

9.

Switches, including pull cords.

10.

Luminaires and lamps.

11.

Lighting control equipment.

12.

Sundry items.

13.

Testing and commissioning.

14.

Where works are to be carried out by a subcontractor, the subcontractor’s preliminaries, design fees, risk allowance, overheads and profit, with allowance for these to be made within unit rate applied to element or component.

Excluded Items (5)
1. Ref: 5.8.4

Specialist lighting systems (included in sub-element 5.8.4).

2. Ref: 8.7.8

Security lights and lighting systems (included in sub-element 8.7.8).

3. Ref: 8.7.9

Street lighting, area lighting and flood lighting (included in sub-element 8.7.9).

4. Ref: 5.12.3

Building management systems and other control systems (included in sub-element 5.12.3).

5. Ref: 5.14

Builder’s work in connection with services (included in element 5.14).