5.12.2-1

Surveillance equipment

Unit: nr/m2 Sub-Element: 5.12.2 - 2 Security systems
Component Information
Code:
5.12.2-1
Sequence:
1
Unit:
nr/m2
Sub-Element:
5.12.2 - 2 Security systems
Description:

Surveillance equipment

Details to State:

details of each type of system to be stated.

Component Statistics
8
Measurement Rules
11
Included Items
4
Excluded Items
Measurement Rules (8)
C1 1

Where components are to be enumerated, the number of components is to be stated.

C2 2

The area measured is the area serviced by the system (i.e. the area of the rooms and circulation spaces that are served by the system, which is not necessarily the total GIFA of the building). The area serviced is measured using the rules of measurement for ascertaining the GIFA.

C3 3

Where more than one system is employed, the area measured for each system is the area serviced by the system.

C4 4

Installations for residential units, hotel rooms, student accommodation units, etc. may be enumerated (nr). The type of residential unit or room, and size (by number of bedrooms) of unit, is to be stated.

C5 5

Work to existing buildings is to be described and identified separately.

C6 6

Where the contractor is only responsible for designing specific elements and/or components of the building project (i.e. not the entire building project), contractor-designed work is to be described and identified separately.

C7 7

State whether external security systems are included with building security systems (cross-reference with sub-element 9.7.8).

C8 8

The percentage additions for testing and commissioning are to be applied to the total cost of the items comprising the sub-element. A single combined percentage addition can be applied to cover the costs of both testing and commissioning.

Included Items (11)
1.

Surveillance equipment (e.g. CCTV), including cameras.

2.

Security detection equipment, including intruder alarms, temperature measurement sensors, occupancy sensors and active infra-red.

3.

Security alarm equipment (i.e. personal attack alarm systems).

4.

Access control systems.

5.

Burglar and security alarms.

6.

Door entry systems (audio (intercom) and visual).

7.

Security lights and lighting systems.

8.

Other security systems, including active infra-red, hand geometry, microwave, passive infra-red, x-ray equipment, metal detection portals and pegging systems.

9.

Sundry items.

10.

Testing and commissioning.

11.

Where works are to be carried out by a subcontractor, the subcontractor’s preliminaries, design fees, risk allowance, overheads and profit, with allowance for these to be made within unit rate applied to element or component.

Excluded Items (4)
1. Ref: 5.8.2

General-purpose LV power supplies (included in sub-element 5.8.2).

2. Ref: 8.7.8

External observation and access control installations, etc. (unless stated otherwise, included in sub-element 8.7.8).

3. Ref: 5.12.3

Building management systems and other control systems (included in sub-element 5.12.3).

4. Ref: 5.14

Builder’s work in connection with services (included in element 5.14).

Export
View as JSON
API Access

Access this component data programmatically: