5.10.1-6

Enclosed hoists

Unit: nr Sub-Element: 5.10.1 - 1 Lifts and enclosed hoists
Component Information
Code:
5.10.1-6
Sequence:
6
Unit:
nr
Sub-Element:
5.10.1 - 1 Lifts and enclosed hoists
Description:

Enclosed hoists

Details to State:

details, including capacity (in kg) and number of levels (nr) serviced, to be stated.

Component Statistics
0
Measurement Rules
6
Included Items
4
Excluded Items
Included Items (6)
1.

Hoists, kitchen service hoists, dumb waiters, etc.

2.

Complete hoist installation, including cages, doors and equipment, guides and counter-balances, and hydraulic and lifting equipment.

3.

Controls and electrical work from, and including, isolator where supplied with installation.

4.

Sundry items.

5.

Testing and commissioning.

6.

Where works are to be carried out by a subcontractor, the subcontractor’s preliminaries, design fees, risk allowance, overheads and profit, with allowance for these to be made within unit rate applied to element or component.

Excluded Items (4)
1. Ref: 1,2

Hoist enclosure or shaft (included in group elements 1 and 2, as appropriate).

2. Ref: 5.8.2

General-purpose LV power supplies (included in sub-element 5.8.2).

3. Ref: 5.12.3

Building management systems and other control systems (included in sub-element 5.12.3).

4. Ref: 5.14

Builder’s work in connection with services (included in element 5.14).

Export