2.3.6-1
Roof features
Component Information
- Code:
- 2.3.6-1
- Sequence:
- 1
- Unit:
- nr
- Sub-Element:
- 2.3.6 - 6 Roof features
Roof features
details to be stated
Component Statistics
Measurement Rules
Included Items
Excluded Items
Measurement Rules (3)
Where components are to be enumerated, the number of components is to be stated.
Work to existing buildings is to be described and identified separately.
Contractor-designed work is to be described and identified separately.
Note: Where the contractor is only responsible for designing specific elements and/or components of the building project (i.e. not the entire building project).Included Items (12)
Turrets.
Wind vanes.
Spires.
False chimneys.
Enclosures designed solely to conceal plant, rooflines, etc. (complete structure, including wall louvers).
Fall arrest systems.
Access systems for cleaning roof.
Roof edge protection (permanent).
Balustrades, handrails, etc. for roof edges and walkways.
Service walkways within roof voids.
Sundry items.
Where works are to be carried out by a subcontractor, the subcontractor’s preliminaries, design fees, risk allowance, overheads and profit, with allowance for these to be made within unit rate applied to element or component.
Excluded Items (6)
Finials (included in sub-element 5.11.3: Finials).
Building Maintenance Units (BMUs) (included in sub-element 2.5.6: Building maintenance systems).
Facade access systems (included in sub-element 2.5.6: Building maintenance systems).
Rooftop wind turbines and wind energy systems (included in sub-element 5.8.5: Wind energy systems).
Photovoltaic tiles, panels, etc. (included in sub-element 5.8.5: Photovoltaic systems).
Solar water collectors, heating panels, etc. (included in sub-element 5.8.5: Solar thermal systems).
Navigation
Export
API Access
Access this component data programmatically:
GET /api/components/2.3.6/1/- Complete component details